mobile-analytical-division
 
 

X-Ray Fluorescence XRF Technology

MWDXRF - Monochromatic Wavelength Dispersive XRF 

1.  ASTM D4929, ASTM D7536

2.  Single Chloride Analyzer (as low as 0.07 ppm, Cl)

     Single Phosphorus Analyzer (as low as 0.4 ppm, PO4)

3. Double Curved Crystal Optics - Lower Detection Limit

    CLORA 2XP       PHOEBE        SINDIE


HDXRF - High Definition XRF

1.  ASTM 4294, EPA 6200, ASTM D8064

2. Multi Elemental Analyzer (12 Elements)

3. Portable on-the-go available

    CADENCE      HD MOBILE    HD PRIME     HD ROCKSAND      PETRA MAX

 

MWDXRF - Monochromatic Wavelength Dispersive XRF

Sindie + Cl - Sulfur and Chlorine Analyzer

REQUEST QUOTATION

TWO critical measurements, ONE push of a button, ZERO hassle

Sindie + Cl is a sulfur and chlorine analyzer delivering two critical measurements with one push of a button and zero hassle. It is the ideal solution for refineries and independent labs to certify sulfur levels in finished products and assess chlorine for corrosion mitigation, all with one instrument. Sindie + Cl utilizes a technique known as Monochromatic Wavelength Dispersive X-ray Fluorescence (MWDXRF) - delivering exceptional reproducibility. Samples are measured directly, which means it can analyze even the heaviest of hydrocarbons like crude oil or coker residuals without the hassle of boats, injectors, furnaces, or changing detectors.

This model utilizes standard XRF sample cups.

       Easy to use

       User-friendly with touch screen interface. Just plug-it-in and measure, results with one touch: power is only utility

 

       Extremely low maintenance

       No conversion gasses, heating elements, quartz tubes or columns

 

       Total Sulfur & Chlorine Analysis

       Certify sulfur levels in finished products and assess chlorine for corrosion mitigation

 

       For use in multiple application areas

       Refinery labs, pipeline terminals, additive plants and inspection laboratories 

 

       Hassle-free sample prep

       Utilizes standard XRF sample cups

 

Calibration curves :   30 calibration curves. Automatic and Manual Calibration                              functionality
Catalysts:   No
Communication Capabilities:     Printer, USB & Ethernet: LIMS Connectivity (optional)
Consumable/Utility Gas:   None
Element:

  Sulfur / 0.4 ppm at 300 s

  Chlorine / 0.3 ppm at 300s

Measurement Time:   User selectable 30-900s
Method Name:   ASTM D2622, ASTM D7039, ASTM D7536, ASTM D4929, & SH/T 0842
Options:   LIMS Connectivity
Range:  

  Sulfur / 0.4 ppm at 5 wt%

  Chlorine / 0.3 ppm - 3000 ppm

Sample Cup Type:   Standard XRF Sample Cups
Sample Matrix:   Hydrocarbons
Specific Technology:   MWDXRF
Type:   Benchtop
Weight:  28 Ibs / 12.7 kg

 

 
 
 