X-Ray Fluorescence XRF Technology

MWDXRF - Monochromatic Wavelength Dispersive XRF 

1.  ASTM D4929, ASTM D7536

2.  Single Chloride Analyzer (as low as 0.07 ppm, Cl)

     Single Phosphorus Analyzer (as low as 0.4 ppm, PO4)

3. Double Curved Crystal Optics - Lower Detection Limit

    CLORA 2XP       PHOEBE        SINDIE


HDXRF - High Definition XRF

1.  ASTM 4294, EPA 6200, ASTM D8064

2. Multi Elemental Analyzer (12 Elements)

3. Portable on-the-go available

    CADENCE      HD MOBILE    HD PRIME     HD ROCKSAND      PETRA MAX

 

MWDXRF - Monochromatic Wavelength Dispersive XRF

Clora 2XP - Chlorine Analyzer

REQUEST QUOTATION

Twice the Precision

Clora 2XP complies with ASTM D7536 and D4929-C standard test methods, and is ideal for testing related to catalyst poisoning in reformers, or for sites with fluid catalytic crackers and hydrocrackers. It delivers twice the precision and offers exceptional analysis for the determination of chlorine in liquid hydrocarbon samples such as aromatics, distillates and heavy fuels, and aqueous solutions. Clora 2XP is powered by the same MWDXRF technology as our signature instrument - Sindie. This direct measurement technique does not require gasses or high temperature processes equating to easy operation and minimum maintenance requirements.

This model delivers a limit of detection of 0.07 ppm and dynamic range up to 3000 ppm (measures catalysts).

         ·         Easy to use

         ·       Extremely low maintenance

         ·         Total chlorine analysis 

         ·         For use in multiple application areas

         ·         Hassle-free sample prep

 

 

 

 

Calibration Curves:   8 calibration curves. Automatic and Manual Calibration functionality   
Catalysts:   No
Communication Capabilities:      Printer, Ethernet: LIMS Connectivity (optional)
Concentration:   In ppm: 5, 10, 50 (crude oil)
Consumable/Utility Gas:   Vacuum
Dimensions: Depth   19.7 in / 50.0 cm
Dimensions: Height   13.4 in / 34.0 cm
Dimensions: Width:   14.6 in / 37.0 cm
Element:   Chlorine / 0.07 ppm
Measurement Time:   User selectable 30-900 s, 300-600 s typical
Method Name:   ASTM D7536, ASTM D4929
Options:   LIMS Connectivity
Range:   0.07 ppm - 2 wt%
Repeatability:

  ppm - r

  Xylene
  0.2 - 0.10
  0.5 - 0.11
  1 - 0.14
  5 - 0.25

  Crude Oil
  5 - 0.4
  10 - 0.6
  50 - 1.2

  Water
  5 - 0.5
  10 - 0.7
  50 - 1.5

Reproducibility:   

  ppm - R

  Xylene
  0.2 - 0.19
  0.5 - 0.22
  1 - 0.27
  5 - 0.50

  Crude Oil
  5 - 0.7
  10 - 1.2
  50 - 2.0

  Water
  5 - 1.0
  10 - 1.4
  50 - 2.5

Sample Cup Type:   Standard XRF Cup
Sample Matrix   Hydrocarbon / Water
Specific Technology   MWDXRF
Type   Benchtop
Weight   70 Ibs / 32kg
XRF Film Type   Prolene
 
 
 
Upcoming Events